Skip to content

SEPS_a130 — Gatedriver Fault

Full alert identifier: SEPS_a130_gatedriverFault

Alert description

The gate driver reported an electrical condition preventing operation.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

The gate driver is reporting an electrical condition affecting its functionality.

Clear condition

All gate driver electrical issues have cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to recover.

Signals to check

These diagnostic fields are associated with SEPS_a130. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Logic Overvoltage SEPS_a130_LogicOvervoltage —
VB Bout Of Range SEPS_a130_VBBoutOfRange —
Vds Overvoltage SEPS_a130_VdsOvervoltage —
Vgs Undervoltage SEPS_a130_VgsUndervoltage —
Vio Undervoltage SEPS_a130_VioUndervoltage —
Vreg Out Of Range SEPS_a130_VregOutOfRange —
Bootstrap Undervoltage SEPS_a130_bootstrapUndervoltage —
Config Mismatch SEPS_a130_configMismatch —
Show 9 more fields
Signal Unit
Driver MIA SEPS_a130_driverMIA —
Eeprom Error SEPS_a130_eepromError —
Fault Pin SEPS_a130_faultPin —
Load Fault SEPS_a130_loadFault —
Overtemperature SEPS_a130_overtemperature —
Power On Reset SEPS_a130_powerOnReset —
Serial Error SEPS_a130_serialError —
Temperature Warning SEPS_a130_temperatureWarning —
Watch Dog Timeout SEPS_a130_watchDogTimeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPS_a130.

Browse all SEPS alert codes