SEPS_a130 — Gatedriver Fault
Full alert identifier: SEPS_a130_gatedriverFault
Alert description
The gate driver reported an electrical condition preventing operation.
Potential impact
The motor is disqualified and system health is degraded.
Set condition
The gate driver is reporting an electrical condition affecting its functionality.
Clear condition
All gate driver electrical issues have cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to recover.
Signals to check
These diagnostic fields are associated with SEPS_a130. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Logic Overvoltage
SEPS_
|
— |
VB Bout Of Range
SEPS_
|
— |
Vds Overvoltage
SEPS_
|
— |
Vgs Undervoltage
SEPS_
|
— |
Vio Undervoltage
SEPS_
|
— |
Vreg Out Of Range
SEPS_
|
— |
Bootstrap Undervoltage
SEPS_
|
— |
Config Mismatch
SEPS_
|
— |
Show 9 more fields
| Signal | Unit |
|---|---|
Driver MIA
SEPS_
|
— |
Eeprom Error
SEPS_
|
— |
Fault Pin
SEPS_
|
— |
Load Fault
SEPS_
|
— |
Overtemperature
SEPS_
|
— |
Power On Reset
SEPS_
|
— |
Serial Error
SEPS_
|
— |
Temperature Warning
SEPS_
|
— |
Watch Dog Timeout
SEPS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPS_a130.