SDCR_a012 — V Boost Sec Irrational

Full alert identifier: SDCR_a012_vBoostSecIrrational

Alert description

Secondary disconnect controller (SDC) boost rail voltage sensor is providing irrational values.

Potential impact

Pyro disconnect may not function as expected.

Set condition

SDC boost rail sensor reading is below operational value while HV backup rail voltage measurement (Vbackup) is at nominal value.

Clear condition

Boost rail sensor voltage reading falls within a nominal / expected range.

Signals to check

These diagnostic fields are associated with SDCR_a012. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
HV Backup Supply V SDCR_a012_HVBackupSupplyV V
Boost Rail V SDCR_a012_boostRailV V
V Bat SDCR_a012_vBat V
Vbkup Good Fdbk SDCR_a012_vbkupGoodFdbk —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a012.