Skip to content

SDCRER_a029 — Di MIA

Full alert identifier: SDCRER_a029_diMIA

Alert description

Drive Inverter (DI) controller area network (CAN) or UART communication to the secondary disconnect controller (SDC) is missing (MIA).

Potential impact

SDC is unable to determine DI status

Set condition

SDC is not receiving all expected CAN or UART frames from DI.

Clear condition

SDC receives all expected CAN and UART frames from DI.

Signals to check

These diagnostic fields are associated with SDCRER_a029. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Can Comms Missing SDCRER_a029_canCommsMissing —
Lv State SDCRER_a029_lvState
0
OFF
1
ON
2
GOING DOWN
3
FAULT
—
Uart Comms Missing SDCRER_a029_uartCommsMissing —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCRER_a029.