Skip to content

SDCREL_a010 — Vref Irrational

Full alert identifier: SDCREL_a010_vrefIrrational

Alert description

Secondary disconnect controller (SDC) reference voltage (Vref) for current sensor measurement is irrational, making SDC unable to monitor drive unit electrical state.

Potential impact

Pyro disconnect may not function as expected.

Set condition

SDC reference voltage (Vref) measurement is outside of expected range.

Clear condition

Reference voltage (Vref) is within expected range.

Signals to check

These diagnostic fields are associated with SDCREL_a010. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Vref SDCREL_a010_Vref V
Boost Rail V SDCREL_a010_boostRailV V
Pgood SDCREL_a010_pgood —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCREL_a010.

Browse all SDCREL alert codes