Skip to content

RSA_a130 — Gatedriver Fault

Full alert identifier: RSA_a130_gatedriverFault

Alert description

The gate driver reported an electrical condition preventing operation.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

The gate driver is reporting an electrical condition affecting its functionality.

Clear condition

All gate driver electrical issues have cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to recover.

Signals to check

These diagnostic fields are associated with RSA_a130. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Logic Overvoltage RSA_a130_LogicOvervoltage —
VB Bout Of Range RSA_a130_VBBoutOfRange —
Vds Overvoltage RSA_a130_VdsOvervoltage —
Vgs Undervoltage RSA_a130_VgsUndervoltage —
Vio Undervoltage RSA_a130_VioUndervoltage —
Vreg Out Of Range RSA_a130_VregOutOfRange —
Bootstrap Undervoltage RSA_a130_bootstrapUndervoltage —
Config Mismatch RSA_a130_configMismatch —
Show 9 more fields
Signal Unit
Driver MIA RSA_a130_driverMIA —
Eeprom Error RSA_a130_eepromError —
Fault Pin RSA_a130_faultPin —
Load Fault RSA_a130_loadFault —
Overtemperature RSA_a130_overtemperature —
Power On Reset RSA_a130_powerOnReset —
Serial Error RSA_a130_serialError —
Temperature Warning RSA_a130_temperatureWarning —
Watch Dog Timeout RSA_a130_watchDogTimeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RSA_a130.

Browse all RSA alert codes