RSA_a130 — Gatedriver Fault
Full alert identifier: RSA_a130_gatedriverFault
Alert description
The gate driver reported an electrical condition preventing operation.
Potential impact
The motor is disqualified and system health is degraded.
Set condition
The gate driver is reporting an electrical condition affecting its functionality.
Clear condition
All gate driver electrical issues have cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to recover.
Signals to check
These diagnostic fields are associated with RSA_a130. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Logic Overvoltage
RSA_
|
— |
VB Bout Of Range
RSA_
|
— |
Vds Overvoltage
RSA_
|
— |
Vgs Undervoltage
RSA_
|
— |
Vio Undervoltage
RSA_
|
— |
Vreg Out Of Range
RSA_
|
— |
Bootstrap Undervoltage
RSA_
|
— |
Config Mismatch
RSA_
|
— |
Show 9 more fields
| Signal | Unit |
|---|---|
Driver MIA
RSA_
|
— |
Eeprom Error
RSA_
|
— |
Fault Pin
RSA_
|
— |
Load Fault
RSA_
|
— |
Overtemperature
RSA_
|
— |
Power On Reset
RSA_
|
— |
Serial Error
RSA_
|
— |
Temperature Warning
RSA_
|
— |
Watch Dog Timeout
RSA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RSA_a130.