Skip to content

RCM2_a406 — Side Accel B Pil R Config

Full alert identifier: RCM2_a406_sideAccelBPilRConfig

Alert description

B-Pillar Right Impact Sensor - Connected but not Configured (Wrong Sensor Connected)

Potential impact

The Safety Restraint System may not perform as designed.

Set condition

There is an issue with the right B-Pillar impact sensor.

Clear condition

The issue is rectified.

Signals to check

These diagnostic fields are associated with RCM2_a406. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Side Accel B Pil R Config S RCM2_a406_sideAccelBPilRConfig_s —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RCM2_a406.

Browse all RCM2 alert codes