RADC_a016 — Adc Over Volt

Full alert identifier: RADC_a016_adcOverVolt

Alert description

ECU Internal ADC Overvoltage - Indicates an over voltage condition for the following voltage rails 1V25, 3V3, 4V5, 5V.

Potential impact

Sensor function will be impaired, radar functions will be unavailable

Set condition

Set when the voltages for the respective rails are above threshold.

Clear condition

Cleared when over voltages return to nominal.

Signals to check

These diagnostic fields are associated with RADC_a016. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Adc Over Volt Type RADC_a016_adcOverVoltType
0
1V25 SMPS OVER VOLTAGE
1
3V3 LIN VOLTAGECO OVER VOLTAGE
2
3V3 LIN PA OVER VOLTAGE
3
3V3 LIN DIGITAL OVER VOLTAGE
4
3V3 LIN ANALOG OVER VOLTAGE
5
3V8 SMPS OVER VOLTAGE
6
4V5 LIN VOLTAGECO OVER VOLTAGE
7
5V SMPS OVER VOLTAGE
—
Adc Voltage RADC_a016_adcVoltage v