Skip to content

RADC_a008 — Ecu Hw Sw Interlock

Full alert identifier: RADC_a008_ecuHwSwInterlock

Alert description

Hardware / Software Interlock Error - the software programmed on the ECU does not match the hardware revision.

Potential impact

Sensor is disabled due to incompatibility and radar functions will not be available

Set condition

When the software programmed in not compatible with the hardware revision

Clear condition

As soon as the right software is programmed on the ECU

Signals to check

These diagnostic fields are associated with RADC_a008. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Inter Lock Err Type RADC_a008_interLockErrType
0
HW SW PROJECT ID INCOMPATIBLE
1
SW VERSION MISMATCH
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RADC_a008.

Browse all RADC alert codes