Skip to content

PSFA_a275 — ECU Mia On Internal Bus

Full alert identifier: PSFA_a275_ECUMiaOnInternalBus

Alert description

The local Electronic Control Unit (ECU) has not received one or more expected Controller Area Network (CAN) messages from the internal steering bus.

Potential impact

Power Steering functionality may be degraded.

Set condition

The local Electronic Control Unit (ECU) did not receive a message it was expecting from the ECUs on the specified internal steering bus within the expected timeout.

Clear condition

The local ECU begins receiving all expected messages from the specified internal steering bus.

Signals to check

These diagnostic fields are associated with PSFA_a275. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Name PSFA_a275_busName
0
SHAFTP
1
RACK
2
SHAFTS
3
HANDWHEEL
—
Controller MIA On Bus PSFA_a275_controllerMIAOnBus —
Ecu Name PSFA_a275_ecuName
0
PEPS
1
SEPS
2
PSFA
3
SSFA
—
Monitor MIA On Bus PSFA_a275_monitorMIAOnBus —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PSFA_a275.

Browse all PSFA alert codes