PSFA_a130 — Gatedriver Fault
Full alert identifier: PSFA_a130_gatedriverFault
Alert description
The gate driver reported an electrical condition preventing operation.
Potential impact
The motor is disqualified and system health is degraded.
Set condition
The gate driver is reporting an electrical condition affecting its functionality.
Clear condition
All gate driver electrical issues have cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to recover.
Signals to check
These diagnostic fields are associated with PSFA_a130. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Logic Overvoltage
PSFA_
|
— |
VB Bout Of Range
PSFA_
|
— |
Vds Overvoltage
PSFA_
|
— |
Vgs Undervoltage
PSFA_
|
— |
Vio Undervoltage
PSFA_
|
— |
Vreg Out Of Range
PSFA_
|
— |
Bootstrap Undervoltage
PSFA_
|
— |
Config Mismatch
PSFA_
|
— |
Show 9 more fields
| Signal | Unit |
|---|---|
Driver MIA
PSFA_
|
— |
Eeprom Error
PSFA_
|
— |
Fault Pin
PSFA_
|
— |
Load Fault
PSFA_
|
— |
Overtemperature
PSFA_
|
— |
Power On Reset
PSFA_
|
— |
Serial Error
PSFA_
|
— |
Temperature Warning
PSFA_
|
— |
Watch Dog Timeout
PSFA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PSFA_a130.