PSFA_a123 — Motor Unit Faulted
Full alert identifier: PSFA_a123_motorUnitFaulted
Alert description
A condition has been detected which prevents steering motor operation. Alert log signal data should provide more information on specific condition(s) involved.
Potential impact
The motor is disqualified and system health is degraded.
Set condition
Motor control inputs exceed acceptable bounds.
Clear condition
Motor control is reset while inputs are within acceptable bounds. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to reset motor controls.
Signals to check
These diagnostic fields are associated with PSFA_a123. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bus Overvoltage
PSFA_
|
— |
Bus Undervoltage
PSFA_
|
— |
Channel
PSFA_
|
— |
Current Continuity
PSFA_
|
— |
Dc Overcurrent
PSFA_
|
— |
Gate Driver
PSFA_
|
— |
Motor Control
PSFA_
|
— |
Over Temperature
PSFA_
|
— |
Show 7 more fields
| Signal | Unit |
|---|---|
Phase Overcurrent A
PSFA_
|
— |
Phase Overcurrent B
PSFA_
|
— |
Phase Overcurrent C
PSFA_
|
— |
Position Sensor
PSFA_
|
— |
Speed
PSFA_
|
rpm |
Torque
PSFA_
|
Nm |
Voltage
PSFA_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PSFA_a123.