Skip to content

PSFA_a123 — Motor Unit Faulted

Full alert identifier: PSFA_a123_motorUnitFaulted

Alert description

A condition has been detected which prevents steering motor operation. Alert log signal data should provide more information on specific condition(s) involved.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Motor control inputs exceed acceptable bounds.

Clear condition

Motor control is reset while inputs are within acceptable bounds. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to reset motor controls.

Signals to check

These diagnostic fields are associated with PSFA_a123. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Overvoltage PSFA_a123_busOvervoltage —
Bus Undervoltage PSFA_a123_busUndervoltage —
Channel PSFA_a123_channel —
Current Continuity PSFA_a123_currentContinuity —
Dc Overcurrent PSFA_a123_dcOvercurrent —
Gate Driver PSFA_a123_gateDriver —
Motor Control PSFA_a123_motorControl —
Over Temperature PSFA_a123_overTemperature —
Show 7 more fields
Signal Unit
Phase Overcurrent A PSFA_a123_phaseOvercurrentA —
Phase Overcurrent B PSFA_a123_phaseOvercurrentB —
Phase Overcurrent C PSFA_a123_phaseOvercurrentC —
Position Sensor PSFA_a123_positionSensor —
Speed PSFA_a123_speed rpm
Torque PSFA_a123_torque Nm
Voltage PSFA_a123_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PSFA_a123.