PM_a061 — DI PM Version Mismatch
Full alert identifier: PM_a061_DIPMVersionMismatch
Alert description
Pedal Monitor Warning: DI and PM versions do not match.
Potential impact
Prevents DI ECU from booting, presents itself as a complete inhibition of drive unit capability.
Set condition
This condition is set when the inter-process communication version between DI and PM is mismatched.
Clear condition
This alert will clear on the next drive cycle.
Signals to check
These diagnostic fields are associated with PM_a061. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Di Ipc Version
PM_
|
— |
Pm Ipc Version
PM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a061.