PM_a036 — Pre Watchdog
Full alert identifier: PM_a036_preWatchdog
Alert description
Pedal Monitor Warning: Pre-watchdog expired.
Potential impact
This alert provides an imminent warning of a likely watchdog reset event.
Set condition
This condition is set the watchdog GPIO pin is set, indicating an immediate watchdog reset is imminent. This alert is intended to collect diagnostic information only.
Clear condition
This alert will clear immediately.
Signals to check
These diagnostic fields are associated with PM_a036. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
In 100 Hz CLK
PM_
|
— |
In 10 Hz CLK
PM_
|
— |
In 1 Hz CLK
PM_
|
— |
In 1 K Hz CLK
PM_
|
— |
In 1 K Hz SWI
PM_
|
— |
In Rx HWI
PM_
|
— |
In Tx HWI
PM_
|
— |
In Tx ISR
PM_
|
— |
Show 7 more fields
| Signal | Unit |
|---|---|
Ovf Stack Id
PM_
|
— |
Time Since 100 Hz Tx SWI
PM_
|
ms |
Time Since 1 K Hz CLK
PM_
|
us |
Time Since 1 K Hz SWI
PM_
|
us |
Time Since Idle
PM_
|
ms |
Time Since Rx HWI
PM_
|
us |
Time Since Tx HWI
PM_
|
us |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a036.