PM_a027 — Eggright3 MIA
Full alert identifier: PM_a027_eggright3MIA
Alert description
The pedal monitor (PM) electronic control unit (ECU) detects that the Etherloop Generalized Gateway Right (EGGRIGHT3) controller area network (CAN) node is missing (MIA).
Potential impact
The PM ECU is unable to monitor the state of the EGGRIGHT3.
Set condition
The PM ECU is not receiving the expected CAN communication from the EGGRIGHT3, and considers it irrational or MIA.
Clear condition
The PM ECU receives the required CAN messages from the EGGRIGHT3.
Signals to check
These diagnostic fields are associated with PM_a027. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Thermal Command 10 Hz
PM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a027.