Skip to content

PMRER_a092 — Xtal Oscillator

Full alert identifier: PMRER_a092_xtalOscillator

Alert description

Pedal Monitor Warning: Crystal oscillator inactive.

Potential impact

Unit may have limited torque or torque disablement with this alert present, see other active alerts for more details.

Set condition

This condition is at application boot when the external crystal is not the active clock source.

Clear condition

This alert does not clear for the duration of the power on cycle once set.

Signals to check

These diagnostic fields are associated with PMRER_a092. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pll Clock Source PMRER_a092_pllClockSource
0
INTOSC2
1
XTAL
2
INTOSC1
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a092.

Browse all PMRER alert codes