Skip to content

PMRER_a012 — Can Data Bus A

Full alert identifier: PMRER_a012_canDataBusA

Alert description

Pedal Monitor Warning: Secondary CAN Integrity Check Failed.

Potential impact

No immediate impact, may lead to indicating an MIA condition for the offending ECU if sustained.

Set condition

This condiiton is set when CAN communication from an offending ECU is intermittent, or fails a communication integrity check on the primary CAN bus.

Clear condition

This alert will clear when CAN communication is re-established with the offending ECU.

Signals to check

These diagnostic fields are associated with PMRER_a012. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bad Value 1 PMRER_a012_badValue1 —
Bad Value 2 PMRER_a012_badValue2 —
Can ID PMRER_a012_canID —
Error Type PMRER_a012_errorType
0
NONE
1
LENGTH SHORT
2
LENGTH LONG
3
CHECKSUM
4
SEQUENCE
5
DATA INVALID
6
UNKNOWN ID
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a012.

Browse all PMRER alert codes