PMREL_a004 — Excessive Decel Torque

Full alert identifier: PMREL_a004_excessiveDecelTorque

Alert description

Pedal Monitor Warning: Deceleration Torque.

Potential impact

The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition torque production error is detected.

Clear condition

This alert will clear on the next drive cycle.

Signals to check

These diagnostic fields are associated with PMREL_a004. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Torque Average PMREL_a004_torqueAverage —
Torque Decel Average PMREL_a004_torqueDecelAverage
-4096
SNA
Nm
Torque Decel Window PMREL_a004_torqueDecelWindow
-4096
SNA
Nm
Torque Measured PMREL_a004_torqueMeasured
-4096
SNA
Nm
Torque Window PMREL_a004_torqueWindow —