Skip to content

PMF_a064 — Torque Intervention

Full alert identifier: PMF_a064_torqueIntervention

Alert description

Pedal Monitor Warning: Torque Intervention.

Potential impact

The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition and indicates diagnostic information in its payload for root cause analysis.

Clear condition

This alert will clear on the next drive cycle.

Signals to check

These diagnostic fields are associated with PMF_a064. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
UI Stopping Mode PMF_a064_UI_stoppingMode
0
STANDARD
1
CREEP
2
HOLD
—
Di Crs State PMF_a064_diCrsState
0
UNAVAILABLE
1
STANDBY
2
ENABLED
3
STANDSTILL
4
OVERRIDE
5
FAULT
6
PRE FAULT
7
PRE CANCEL
—
Intervention Type PMF_a064_interventionType —
Pm Crs State PMF_a064_pmCrsState
0
UNAVAILABLE
1
STANDBY
2
ENABLED
3
STANDSTILL
4
OVERRIDE
5
FAULT
6
PRE FAULT
7
PRE CANCEL
—
Short Detected By DI PMF_a064_shortDetectedByDI —
Torque Cmd State PMF_a064_torqueCmdState
0
SNA
6
Valid
8
Invalid
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMF_a064.

Browse all PMF alert codes