Skip to content

PEPS_a159 — Current Continuity Fault

Full alert identifier: PEPS_a159_currentContinuityFault

Alert description

Steering motor current continuity is irrational. The sum of the three phase currents is not equal to 0.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Observed current into motor does not match current exiting.

Clear condition

Current returns to nominal.

Signals to check

These diagnostic fields are associated with PEPS_a159. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Phase A Current PEPS_a159_phaseACurrent A
Phase B Current PEPS_a159_phaseBCurrent A
Phase C Current PEPS_a159_phaseCCurrent A
Sum Current PEPS_a159_sumCurrent amp

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PEPS_a159.

Browse all PEPS alert codes