Skip to content

PCS2_a130 — IONVMM Server Retry Event

Full alert identifier: PCS2_a130_IONVMMServerRetryEvent

Alert description

The Non-Volatile Memory (NVM) server encountered at least one error during initialization

Potential impact

NVM record servicing is not possible, making Power Conversion System (PCS2) functionality limited or unavailable

Set condition

A step in the NVM server initialization sequence returns an error indication

Clear condition

The NVM server reached a state where it is able to service NVM record requests

Signals to check

These diagnostic fields are associated with PCS2_a130. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Retries Attempted PCS2_a130_retriesAttempted —
Server State At Retry PCS2_a130_serverStateAtRetry
0
SYSTEM START
1
SPI INITIALIZED
2
NVMM LAYER INITIALIZED
3
READY TO RUN
4
REFORMAT REQUEST PENDING
5
RETRIES EXPIRED PRE NVMM INIT
6
RETRIES EXPIRED POST NVMM INIT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a130.

Browse all PCS2 alert codes