Skip to content

PCS2_a128 — Cyclo Bgdps Health Check Failed

Full alert identifier: PCS2_a128_cycloBgdpsHealthCheckFailed

Alert description

The Power Conversion System (PCS2) has failed the self-performed Gate Drive Power Supply (GDPS) health check on Cyclo Converter B

Potential impact

AC charging and Powershare functionality may be limited or paused

Set condition

The PCS2 ECU does not pass the self-performed GDPS health check on Cyclo Converter B

Clear condition

Cyclo Converter B GDPS health check passes

Signals to check

These diagnostic fields are associated with PCS2_a128. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ac Line Clk Health Status PCS2_a128_acLineClkHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 L 1 Enable Health Status PCS2_a128_dcac2_L1EnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 L 2 Enable Health Status PCS2_a128_dcac2_L2EnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 L 3 Enable Health Status PCS2_a128_dcac2_L3EnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 LN Enable Health Status PCS2_a128_dcac2_LNEnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 Ac Tank Clk Health Status PCS2_a128_dcac2_acTankClkHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 Dc Tank Clk Health Status PCS2_a128_dcac2_dcTankClkHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 2 Hv Enable Health Status PCS2_a128_dcac2_hvEnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a128.

Browse all PCS2 alert codes