PCS2_a128 — Cyclo Bgdps Health Check Failed
Full alert identifier: PCS2_a128_cycloBgdpsHealthCheckFailed
Alert description
The Power Conversion System (PCS2) has failed the self-performed Gate Drive Power Supply (GDPS) health check on Cyclo Converter B
Potential impact
AC charging and Powershare functionality may be limited or paused
Set condition
The PCS2 ECU does not pass the self-performed GDPS health check on Cyclo Converter B
Clear condition
Cyclo Converter B GDPS health check passes
Signals to check
These diagnostic fields are associated with PCS2_a128. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac Line Clk Health Status
PCS2_
|
— |
Dcac 2 L 1 Enable Health Status
PCS2_
|
— |
Dcac 2 L 2 Enable Health Status
PCS2_
|
— |
Dcac 2 L 3 Enable Health Status
PCS2_
|
— |
Dcac 2 LN Enable Health Status
PCS2_
|
— |
Dcac 2 Ac Tank Clk Health Status
PCS2_
|
— |
Dcac 2 Dc Tank Clk Health Status
PCS2_
|
— |
Dcac 2 Hv Enable Health Status
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a128.