Skip to content

PCS2_a105 — Line To Line Rms UV

Full alert identifier: PCS2_a105_LineToLineRmsUV

Alert description

The root mean squared (RMS) voltage from Line to Line has decreased below the expected RMS voltage threshold

Potential impact

AC charging and AC outlet functionality may be limited or paused

Set condition

The root mean squared (RMS) voltage from Line to Line has decreased below the expected RMS voltage threshold

Clear condition

The root mean squared (RMS) voltage from Line to Line has no longer decreased below the expected RMS voltage threshold

Signals to check

These diagnostic fields are associated with PCS2_a105. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Itic Curve Section PCS2_a105_iticCurveSection
0
ITIC CURVE SECTION STEADY STATE UV
1
ITIC CURVE SECTION LINE VOLTAGE SAG LEVEL 1 UV
2
ITIC CURVE SECTION LINE VOLTAGE SAG LEVEL 2 UV
3
NUM ITIC CURVE UV SECTIONS
—
Line To Line Voltage Rms PCS2_a105_lineToLineVoltageRms V
Lines Faulted PCS2_a105_linesFaulted
0
L1LN
1
L2LN
2
L3LN
3
L1L2
4
L1L3
5
L2L3
6
NUM AC LINE TO LINE
—
Under Voltage Rms Threshold PCS2_a105_underVoltageRmsThreshold V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a105.

Browse all PCS2 alert codes