Skip to content

PCS2_a094 — Ac Charging Unavailable

Full alert identifier: PCS2_a094_acChargingUnavailable

Alert description

The Power Conversion System (PCS) detects a condition causing AC charging to be unavailable.

Potential impact

The vehicle will be unable to AC charge as expected.

Set condition

PCS detects a condition causing AC charging to be unavailable. See alert log signal data for more information.

Clear condition

PCS no longer detects the condition affecting AC charging functionality.

Signals to check

These diagnostic fields are associated with PCS2_a094. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cyclo A Blocked Reason PCS2_a094_cycloABlockedReason
0
NOT BLOCKED
1
BLOCKED DUE TO OVER TEMP
2
BLOCKED DUE TO HVDC OVER CURRENT
3
BLOCKED DUE TO HEALTH CHECK FAILED
4
BLOCKED DUE TO AUX RAIL PERMANENT FAULT
5
NUM BLOCKED REASONS
—
Cyclo B Blocked Reason PCS2_a094_cycloBBlockedReason
0
NOT BLOCKED
1
BLOCKED DUE TO OVER TEMP
2
BLOCKED DUE TO HVDC OVER CURRENT
3
BLOCKED DUE TO HEALTH CHECK FAILED
4
BLOCKED DUE TO AUX RAIL PERMANENT FAULT
5
NUM BLOCKED REASONS
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a094.

Browse all PCS2 alert codes