PCS2_a062 — Ac Voltage Not Present

Full alert identifier: PCS2_a062_acVoltageNotPresent

Alert description

AC voltage is not present while the The Power Conversion System (PCS) is expecting AC voltage to be provided by the external charging equipment

Potential impact

AC charging functionality may be unavailable

Set condition

The PCS does not detect AC input voltage while being commanded to charge

Clear condition

The PCS stops being commanded to AC charge

Signals to check

These diagnostic fields are associated with PCS2_a062. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ac L 1 L 2 Vrms PCS2_a062_acL1L2Vrms V
Ac L 1 L 3 Vrms PCS2_a062_acL1L3Vrms V
Ac L 1 N Vrms PCS2_a062_acL1NVrms V
Ac L 2 L 3 Vrms PCS2_a062_acL2L3Vrms V
Ac L 2 N Vrms PCS2_a062_acL2NVrms V
Ac L 3 N Vrms PCS2_a062_acL3NVrms V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a062.

Browse all PCS2 alert codes