PCS2_a059 — Dcdc Enable Line Deasserted
Full alert identifier: PCS2_a059_dcdcEnableLineDeasserted
Alert description
The Power Conversion System (PCS) detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate.
Potential impact
DCDC converter will be forced shutdown due to this ENABLE line deassertion
Set condition
The PCS detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate
Clear condition
The DCDC enable digital line is reasserted or the DCDC is commanded to go back to standby
Signals to check
These diagnostic fields are associated with PCS2_a059. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dcdc Hvc Enable Line Status
PCS2_
|
— |
Dcdc Hvc Enable Line TZ Latched Bit
PCS2_
|
— |
Dcdc Request
PCS2_
|
— |
Dcdc Stage Request Processed
PCS2_
|
— |
Dcdc Stage State
PCS2_
|
— |
Dcdc Vcr Enable Line Status
PCS2_
|
— |
Dcdc Vcr Enable Line TZ Latched Bit
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a059.