Skip to content

PCS2_a059 — Dcdc Enable Line Deasserted

Full alert identifier: PCS2_a059_dcdcEnableLineDeasserted

Alert description

The Power Conversion System (PCS) detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate.

Potential impact

DCDC converter will be forced shutdown due to this ENABLE line deassertion

Set condition

The PCS detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate

Clear condition

The DCDC enable digital line is reasserted or the DCDC is commanded to go back to standby

Signals to check

These diagnostic fields are associated with PCS2_a059. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dcdc Hvc Enable Line Status PCS2_a059_dcdcHvcEnableLineStatus —
Dcdc Hvc Enable Line TZ Latched Bit PCS2_a059_dcdcHvcEnableLineTZLatchedBit —
Dcdc Request PCS2_a059_dcdcRequest
0
OFF
1
LV REGULATION
2
HV REGULATION
—
Dcdc Stage Request Processed PCS2_a059_dcdcStageRequestProcessed
0
DISABLE
1
LV REGULATION
2
HV PRECHARGE
3
HV DISCHARGE
—
Dcdc Stage State PCS2_a059_dcdcStageState
0
POWER UP INIT
1
STANDBY
2
PRECONDITION
3
ACTIVE
4
FAULTED
5
NUM STATES
—
Dcdc Vcr Enable Line Status PCS2_a059_dcdcVcrEnableLineStatus —
Dcdc Vcr Enable Line TZ Latched Bit PCS2_a059_dcdcVcrEnableLineTZLatchedBit —