Skip to content

PCS2_a012 — Cyclo A Tank Over Current

Full alert identifier: PCS2_a012_cycloATankOverCurrent

Alert description

The DCAC converter A (DCACA) resonant tank current goes above the allowed current threshold

Potential impact

AC charging and AC outlet functionality may be limited or paused

Set condition

The pack side DCDC converter (DCACA) resonant tank current goes above the allowed current threshold

Clear condition

The DCAC system retries

Signals to check

These diagnostic fields are associated with PCS2_a012. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cyclo A Tank Over Current Trip PCS2_a012_cycloATankOverCurrentTrip
0
COMPH TRIP
1
COMPL TRIP
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a012.

Browse all PCS2 alert codes