PCS2REXB_a148 — Ac Relay Voltage Irrational
Full alert identifier: PCS2REXB_a148_acRelayVoltageIrrational
Alert description
The Power Conversion System (PCS2) detects the voltage sensor readings before and after the AC relay does not match the expected behavior of the given AC relay state.
Potential impact
DCAC functionality may be limited or paused.
Set condition
The AC relay voltage difference exceeds the expected threshold.
Clear condition
The AC relay voltage difference is within the expected threshold.
Signals to check
These diagnostic fields are associated with PCS2REXB_a148. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac Relay State
PCS2REXB_
|
— |
L 1 N Post Relay Voltage
PCS2REXB_
|
V |
L 2 N Post Relay Voltage
PCS2REXB_
|
V |
L 2 N Pre Relay Voltage
PCS2REXB_
|
V |
L 3 N Post Relay Voltage
PCS2REXB_
|
V |
L 3 N Pre Relay Voltage
PCS2REXB_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a148.