Skip to content

PCS2REXB_a142 — Ac Line Gdps Uncalibrated

Full alert identifier: PCS2REXB_a142_AcLineGdpsUncalibrated

Alert description

The Power Conversion System (PCS) AC line Gate Drive Power Supply (GDPS) has not been correctly calibrated

Potential impact

The PCS will use inaccurate GDPS calibration data, which may stress the AC line MOSFETS.

Set condition

The AC line GDPS calibration data is not present in NVM (AcLineGdpsDataMissing=1), or is not validated (AcLineGdpsDataOutOfSpec=1), or is stale (AcLineGdpsDataStale=1)

Clear condition

The PCS AC line GDPS calibration data is correctly calibrated

Signals to check

These diagnostic fields are associated with PCS2REXB_a142. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ac Line Gdps Data Missing PCS2REXB_a142_AcLineGdpsDataMissing —
Ac Line Gdps Data Out Of Spec PCS2REXB_a142_AcLineGdpsDataOutOfSpec —
Ac Line Gdps Data Stale PCS2REXB_a142_AcLineGdpsDataStale —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a142.

Browse all PCS2REXB alert codes