PCS2REXB_a132 — Microgrid Droop Detected

Full alert identifier: PCS2REXB_a132_microgridDroopDetected

Alert description

The Power Conversion System (PCS2) detects the microgrid frequency droops below its nominal level indicating microgrid is under heavy load

Potential impact

AC charging power will be temporarily limited depending on the droop level to reduce the load on the microgrid

Set condition

The PCS2 ECU detects the microgrid frequency droops below its nominal level

Clear condition

Microgrid no longer detected

Signals to check

These diagnostic fields are associated with PCS2REXB_a132. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
L 1 N Grid Voltage PCS2REXB_a132_L1NGridVoltage V
L 2 N Grid Voltage PCS2REXB_a132_L2NGridVoltage V
L 3 N Grid Voltage PCS2REXB_a132_L3NGridVoltage V
Current Limit PCS2REXB_a132_currentLimit A
Grid Frequency PCS2REXB_a132_gridFrequency Hz

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a132.

Browse all PCS2REXB alert codes