PCS2REXB_a103 — Iso Temp Sensor Irrational
Full alert identifier: PCS2REXB_a103_IsoTempSensorIrrational
Alert description
An isolated temperature sensor measurement becomes irrational
Potential impact
DCDC, AC charging, and AC outlet functionality may be limited or paused
Set condition
An isolated temperature sensor measurement timing is beyond rational limits
Clear condition
An isolated temperature sensor measurement timing falls back within rational limits
Signals to check
These diagnostic fields are associated with PCS2REXB_a103. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Closed Loop Time
PCS2REXB_
|
nS |
Fall Time Open Loop
PCS2REXB_
|
nS |
Iso Temp Sense Irrational
PCS2REXB_
|
— |
Iso Temp Sense Out Of Bounds
PCS2REXB_
|
— |
Iso Temp Sensor
PCS2REXB_
|
— |
Iso Temp Sensor Fall Time Out Of Bounds
PCS2REXB_
|
— |
Iso Temp Sensor MIA
PCS2REXB_
|
— |
Iso Temp Sensor Rise Fall Mismatch
PCS2REXB_
|
— |
Show 2 more fields
| Signal | Unit |
|---|---|
Iso Temp Sensor Rise Time Out Of Bounds
PCS2REXB_
|
— |
Rise Time Open Loop
PCS2REXB_
|
nS |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a103.