PCS2REXB_a100 — Line To Line Rms OV
Full alert identifier: PCS2REXB_a100_LineToLineRmsOV
Alert description
The root mean squared (RMS) voltage from AC Line to Line has exceeded the expected RMS voltage threshold
Potential impact
AC charging and AC outlet functionality may be limited or paused
Set condition
The RMS voltage from AC Line to Line has exceeded the expected RMS voltage threshold
Clear condition
The RMS voltage from AC Line to Line has no longer exceeded the expected RMS voltage threshold
Signals to check
These diagnostic fields are associated with PCS2REXB_a100. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Itic Curve Section
PCS2REXB_
|
— |
Line To Line Voltage Rms
PCS2REXB_
|
V |
Lines Faulted
PCS2REXB_
|
— |
Over Voltage Rms Threshold
PCS2REXB_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a100.