PCS2REXB_a064 — Dcdc A Tank Parameters Out Of Spec
Full alert identifier: PCS2REXB_a064_dcdcATankParametersOutOfSpec
Alert description
The pack side DCDC converter (DCDCA) resonant tank calibration data is out of specification
Potential impact
DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching
Set condition
A tank capacitance or inductance measurement for DCDCA is not within the design margin
Clear condition
DCDCA resonant tank calibration data is within specification
Signals to check
These diagnostic fields are associated with PCS2REXB_a064. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Capacitance
PCS2REXB_
|
nF |
Capacitance Out Of Spec
PCS2REXB_
|
— |
Leakage Inductance
PCS2REXB_
|
uH |
Leakage Inductance Out Of Spec
PCS2REXB_
|
— |
Magnetizing Inductance
PCS2REXB_
|
uH |
Magnetizing Inductance Out Of Spec
PCS2REXB_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a064.