PCS2REXB_a064 — Dcdc A Tank Parameters Out Of Spec

Full alert identifier: PCS2REXB_a064_dcdcATankParametersOutOfSpec

Alert description

The pack side DCDC converter (DCDCA) resonant tank calibration data is out of specification

Potential impact

DCDC operation allowed with default resonant tank parameters, but risk of damaging the converter due to hard switching

Set condition

A tank capacitance or inductance measurement for DCDCA is not within the design margin

Clear condition

DCDCA resonant tank calibration data is within specification

Signals to check

These diagnostic fields are associated with PCS2REXB_a064. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Capacitance PCS2REXB_a064_capacitance nF
Capacitance Out Of Spec PCS2REXB_a064_capacitanceOutOfSpec —
Leakage Inductance PCS2REXB_a064_leakageInductance uH
Leakage Inductance Out Of Spec PCS2REXB_a064_leakageInductanceOutOfSpec —
Magnetizing Inductance PCS2REXB_a064_magnetizingInductance uH
Magnetizing Inductance Out Of Spec PCS2REXB_a064_magnetizingInductanceOutOfSpec —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a064.

Browse all PCS2REXB alert codes