PCS2REXB_a053 — Hv Dcdc Control MIA
Full alert identifier: PCS2REXB_a053_hvDcdcControlMIA
Alert description
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the High Voltage Processor (HVP)
Potential impact
AC charging and AC outlet functionality may be unavailable
Set condition
The PCS does not receive all expected CAN messages from high voltage processor
Clear condition
The PCS receives all expected CAN messages from high voltage processor
Signals to check
These diagnostic fields are associated with PCS2REXB_a053. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
HVP Hvs Control
PCS2REXB_
|
— |
HV Dcdc Control
PCS2REXB_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a053.