Skip to content

PCS2REXB_a039 — Hv Bus Top Under Voltage

Full alert identifier: PCS2REXB_a039_hvBusTopUnderVoltage

Alert description

The sensor measuring the top half of the high voltage (HV) bus voltage detects a value below the allowed voltage threshold

Potential impact

DCDC functionality may be limited or paused

Set condition

The sensor measuring the top half of the HV bus voltage goes below the allowed voltage threshold

Clear condition

The DCDC system retries

Signals to check

These diagnostic fields are associated with PCS2REXB_a039. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hv Bus Bot Voltage PCS2REXB_a039_hvBusBotVoltage V
Hv Bus Top Voltage PCS2REXB_a039_hvBusTopVoltage V
Hv Bus Voltage PCS2REXB_a039_hvBusVoltage V
Voltage Fault Threshold PCS2REXB_a039_voltageFaultThreshold V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a039.

Browse all PCS2REXB alert codes