PCS2REXB_a021 — Power Rail Under Voltage

Full alert identifier: PCS2REXB_a021_powerRailUnderVoltage

Alert description

The generated power rail (4.5V, 10V, or 18V) has gone lower than the allowed lower threshold

Potential impact

DCDC, AC charging, and outlet functionality may be limited or paused

Set condition

The power rail (4.5V, 10V or 18V) has gone lower than the allowed lower threshold

Clear condition

The power rail (4.5V, 10V or 18V) returns above the allowed lower threshold

Signals to check

These diagnostic fields are associated with PCS2REXB_a021. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
10 V 0 Rail Under Voltage Threshold PCS2REXB_a021_10V0RailUnderVoltageThreshold
4095
SNA
V
10 V 0 Rail Under Voltage Trip PCS2REXB_a021_10V0RailUnderVoltageTrip —
18 V 0 Rail Under Voltage Threshold PCS2REXB_a021_18V0RailUnderVoltageThreshold
4095
SNA
V
18 V 0 Rail Under Voltage Trip PCS2REXB_a021_18V0RailUnderVoltageTrip —
4 V 5 Rail Under Voltage Threshold PCS2REXB_a021_4V5RailUnderVoltageThreshold
4095
SNA
V
4 V 5 Rail Under Voltage Trip PCS2REXB_a021_4V5RailUnderVoltageTrip —