PCS2REXB_a014 — Cyclo B Tank Over Current

Full alert identifier: PCS2REXB_a014_cycloBTankOverCurrent

Alert description

The DCAC converter B (DCACB) resonant tank current goes above the allowed current threshold

Potential impact

AC charging and AC outlet functionality may be limited or paused

Set condition

The DCACB resonant tank current goes above the allowed current threshold

Clear condition

The DCAC system retries

Signals to check

These diagnostic fields are associated with PCS2REXB_a014. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cyclo B Tank Over Current Trip PCS2REXB_a014_cycloBTankOverCurrentTrip
0
COMPH TRIP
1
COMPL TRIP
—