PCS2REXA_a149 — Buck Boost Fault

Full alert identifier: PCS2REXA_a149_buckBoostFault

Alert description

The Power Conversion System (PCS) is unable to regulate internal voltage rails.

Potential impact

DCDC conversion, AC charging, and outlets may be unavailable.

Set condition

The buck-boost converter did not reach the desired voltage.

Clear condition

The buck-boost converter voltage reaches the desired voltage.

Signals to check

These diagnostic fields are associated with PCS2REXA_a149. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Buck Boost 18 V 0 Rail PCS2REXA_a149_buckBoost18V0Rail
4095
SNA
V
Buck Boost 18 VOV Cmpss Fault PCS2REXA_a149_buckBoost18VOVCmpssFault —
Buck Boost 18 VUV Cmpss Fault PCS2REXA_a149_buckBoost18VUVCmpssFault —
Buck Boost Cmpss Fault Count PCS2REXA_a149_buckBoostCmpssFaultCount —
Buck Boost LVOV Cmpss Fault PCS2REXA_a149_buckBoostLVOVCmpssFault —
Buck Boost LVUV Cmpss Fault PCS2REXA_a149_buckBoostLVUVCmpssFault —
Buck Boost Permanent Fault PCS2REXA_a149_buckBoostPermanentFault —
Buck Boost Ramp Fault Count PCS2REXA_a149_buckBoostRampFaultCount —
Show 2 more fields
Signal Unit
Buck Boost Ramp Target PCS2REXA_a149_buckBoostRampTarget
4095
SNA
V
Buck Boost Retry Prevented Fault PCS2REXA_a149_buckBoostRetryPreventedFault —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a149.

Browse all PCS2REXA alert codes