PCS2REXA_a129 — Loss Of Zcd Event Control
Full alert identifier: PCS2REXA_a129_lossOfZcdEventControl
Alert description
The Power Conversion System (PCS2) has detected that one of its DCDC stage's resonant tank current zero-crossing event measured timing is continuously out of our control
Potential impact
The impacted DCDC stage may have a hardware integrity issue and may not be able to deliver power to its output
Set condition
The Power Conversion System (PCS2) has detected the resonant tank's zero-crossing behavior is out of its control, resulting in zero-crossing event measured timing being irrational
Clear condition
The Power Conversion System (PCS2) no longer detects the irrational resonant tank current zero-crossing event measurement on that DCDC stage
Signals to check
These diagnostic fields are associated with PCS2REXA_a129. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Commanded Switch Freq
PCS2REXA_
|
kHz |
Hv Bus Voltage
PCS2REXA_
|
V |
Instant Measured ZCD Event
PCS2REXA_
|
ns |
Instant Measured ZCD Half Prd PU
PCS2REXA_
|
— |
Lv Bus Voltage
PCS2REXA_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a129.