Skip to content

PCS2REXA_a127 — Cyclo Agdps Health Check Failed

Full alert identifier: PCS2REXA_a127_cycloAgdpsHealthCheckFailed

Alert description

The Power Conversion System (PCS2) has failed the self-performed Gate Drive Power Supply (GDPS) health check on Cyclo Converter A

Potential impact

AC charging and Powershare functionality may be limited or paused

Set condition

The PCS2 ECU does not pass the self-performed GDPS health check on Cyclo Converter A

Clear condition

Cyclo Converter A GDPS health check passes

Signals to check

These diagnostic fields are associated with PCS2REXA_a127. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ac Line Clk Health Status PCS2REXA_a127_acLineClkHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 L 1 Enable Health Status PCS2REXA_a127_dcac1_L1EnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 L 2 Enable Health Status PCS2REXA_a127_dcac1_L2EnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 L 3 Enable Health Status PCS2REXA_a127_dcac1_L3EnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 LN Enable Health Status PCS2REXA_a127_dcac1_LNEnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 Ac Tank Clk Health Status PCS2REXA_a127_dcac1_acTankClkHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 Dc Tank Clk Health Status PCS2REXA_a127_dcac1_dcTankClkHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—
Dcac 1 Hv Enable Health Status PCS2REXA_a127_dcac1_hvEnableHealthStatus
0
UNDETERMINED
1
HEALTHY
2
UNHEALTHY
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a127.

Browse all PCS2REXA alert codes