PCS2REXA_a067 — Cyclo B Tank Parameters Out Of Spec
Full alert identifier: PCS2REXA_a067_cycloBTankParametersOutOfSpec
Alert description
DCAC converter A (DCACA) resonant tank calibration data is out of specification
Potential impact
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
Set condition
A tank capacitance or inductance measurement for DCACA is not withinthe design margin
Clear condition
DCACA resonant tank calibration data is within specification
Signals to check
These diagnostic fields are associated with PCS2REXA_a067. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Capacitance
PCS2REXA_
|
nF |
Capacitance Out Of Spec
PCS2REXA_
|
— |
Leakage Inductance
PCS2REXA_
|
uH |
Leakage Inductance Out Of Spec
PCS2REXA_
|
— |
Magnetizing Inductance
PCS2REXA_
|
uH |
Magnetizing Inductance Out Of Spec
PCS2REXA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a067.