Skip to content

PCS2REXA_a063 — Chg Unknown Grid Config

Full alert identifier: PCS2REXA_a063_chgUnknownGridConfig

Alert description

The Power Conversion System (PCS) detects an unknown grid configuration from the external charging equipment

Potential impact

AC charging functionality may be unavailable

Set condition

The PCS detects unknown grid configuration

Clear condition

The PCS stops being commanded to AC charge

Signals to check

These diagnostic fields are associated with PCS2REXA_a063. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
L 1 L 2 Available For Charging PCS2REXA_a063_L1L2AvailableForCharging —
L 1 L 3 Available For Charging PCS2REXA_a063_L1L3AvailableForCharging —
L 1 N Available For Charging PCS2REXA_a063_L1NAvailableForCharging —
L 2 L 3 Available For Charging PCS2REXA_a063_L2L3AvailableForCharging —
L 2 N Available For Charging PCS2REXA_a063_L2NAvailableForCharging —
L 3 N Available For Charging PCS2REXA_a063_L3NAvailableForCharging —
Phase Diff L 1 L 3 L 2 L 3 PCS2REXA_a063_phase_diff_L1L3_L2L3 Deg
Phase Diff L 1 N L 2 N PCS2REXA_a063_phase_diff_L1N_L2N Deg
Show 2 more fields
Signal Unit
Phase Diff L 1 N L 3 N PCS2REXA_a063_phase_diff_L1N_L3N Deg
Phase Diff L 2 N L 3 N PCS2REXA_a063_phase_diff_L2N_L3N Deg

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a063.

Browse all PCS2REXA alert codes