Skip to content

PCS2REXA_a051 — Bms Mia

Full alert identifier: PCS2REXA_a051_bmsMia

Alert description

The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Battery Management System (BMS)

Potential impact

DCDC, AC charging, and AC outlet functionality may be unavailable

Set condition

The PCS does not receive all expected CAN messages from the BMS

Clear condition

The PCS receives all expected CAN messages from the BMS

Signals to check

These diagnostic fields are associated with PCS2REXA_a051. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
BMS Charge Status PCS2REXA_a051_BMS_chargeStatus —
BMS Grid Form Control PCS2REXA_a051_BMS_gridFormControl —
BMS Pack Config PCS2REXA_a051_BMS_packConfig —
BMS Pcs Limits PCS2REXA_a051_BMS_pcsLimits —
BMS Pcs Request PCS2REXA_a051_BMS_pcsRequest —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a051.