IBST_a122 — RPS Vector Oscillating
Full alert identifier: IBST_a122_RPSVectorOscillating
Alert description
iBooster (IBST) detected Rotation Position Sensor (RPS) raw signals (sine and cosine): Vector length oscillating.
Potential impact
IBST may not operate as expected.
Set condition
IBST detected RPS raw signals (sine and cosine): Vector length oscillating.
Clear condition
iBooster can not recover from this condition. iBooster replacement may be required.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of IBST_a122.