IBST_a111 — Li PS1 Sent Line Low
Full alert identifier: IBST_a111_LiPS1SentLineLow
Alert description
iBooster (IBST) detected linear position sensor channel 1 line shorted to ground.
Potential impact
IBST may not operate as expected.
Set condition
IBST detects linear position sensor channel 1 line shorted to ground.
Clear condition
iBooster can not recover from this condition. iBooster replacement may be required.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of IBST_a111.