IBST_a065 — Temp Sens2 Short To Ground
Full alert identifier: IBST_a065_tempSens2ShortToGround
Alert description
iBooster (IBST) detected Brushless Motor (BLM) temperature sensor 2 line shorted to ground.
Potential impact
IBST may not operate as expected.
Set condition
IBST detects BLM temperature sensor 2 line shorted to ground.
Clear condition
iBooster can not recover from this condition. iBooster replacement may be required.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of IBST_a065.