HVREX_a730 — Bandolier Model Reset

Full alert identifier: HVREX_a730_BandolierModelReset

Alert description

The Bandolier Thermal Model for the battery pack was reset to thermistor temperatures

Potential impact

Modeled thermal gradient across pack will be reset to thermistor temperatures

Set condition

The absolute delta between the modeled thermistor temperature and the actual is greater than than the reset threshold OR the model inputs become valid

Clear condition

The absolute delta between the modeled thermistor temperature and the actual is less than than the reset threshold AND the model inputs become valid

Signals to check

These diagnostic fields are associated with HVREX_a730. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temp Invalid HVREX_a730_ambientTempInvalid —
Bando Thm Model State HVREX_a730_bandoThmModelState —
Brick Dissipation Invalid HVREX_a730_brickDissipationInvalid —
Flow Rate Invalid HVREX_a730_flowRateInvalid —
Inlet Coolant Temp Invalid HVREX_a730_inletCoolantTempInvalid —
Sanity Check Failed HVREX_a730_sanityCheckFailed —
Temp Delta 1 HVREX_a730_tempDelta1 C
Temp Delta 2 HVREX_a730_tempDelta2 C
Show 3 more fields
Signal Unit
Temp Delta 3 HVREX_a730_tempDelta3 C
Temp Delta 4 HVREX_a730_tempDelta4 C
Thermistor Temps Invalid HVREX_a730_thermistorTempsInvalid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a730.

Browse all HVREX alert codes