Skip to content

HVREX_a209 — Shunt Sense Current Mismatch

Full alert identifier: HVREX_a209_ShuntSenseCurrentMismatch

Alert description

Shunt active sense and passive sense readings are not in agreement

Potential impact

Vehicle may not drive or charge.

Set condition

Shunt active sense and passive sense readings have a delta outside of the acceptable margin

Clear condition

Shunt active sense and passive sense readings have a delta within the acceptable margin

Signals to check

These diagnostic fields are associated with HVREX_a209. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Shunt Current HVREX_a209_shuntCurrent
-8388608
SNA
A
Shunt Passive Current HVREX_a209_shuntPassiveCurrent
-8388608
SNA
A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a209.

Browse all HVREX alert codes