HVREX_a209 — Shunt Sense Current Mismatch
Full alert identifier: HVREX_a209_ShuntSenseCurrentMismatch
Alert description
Shunt active sense and passive sense readings are not in agreement
Potential impact
Vehicle may not drive or charge.
Set condition
Shunt active sense and passive sense readings have a delta outside of the acceptable margin
Clear condition
Shunt active sense and passive sense readings have a delta within the acceptable margin
Signals to check
These diagnostic fields are associated with HVREX_a209. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Shunt Current
HVREX_
|
A |
Shunt Passive Current
HVREX_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a209.