Skip to content

HVREX_a154 — Fc Neg Ctr Open Fail Aux Still Closed

Full alert identifier: HVREX_a154_FcNegCtrOpenFailAuxStillClosed

Alert description

Negative contactor is expected to be open but aux reports them as still closed.

Potential impact

Firmware will try to open the contactor again.

Set condition

Contactor state timed out of the OPENING state (and transitioned to AUX_MISMATCH) due to aux reporting the contactor as still closed.

Clear condition

Contactor state is OPEN or PULLED_IN.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a154.