HVREX_a058 — Bmb Vref Bad
Full alert identifier: HVREX_a058_BmbVrefBad
Alert description
Indicates a Battery Monitoring Board (BMB) reference voltage has continuously been out of bounds
Potential impact
Other BMB voltage signals will be substituted given the reference voltage is unreliable
Set condition
Any BMB reference voltage has continuously deviated outside the in-bounds threshold of the nominal voltage
Clear condition
All BMB reference voltages continuously remain within the in-bounds threshold of the nominal voltage
Signals to check
These diagnostic fields are associated with HVREX_a058. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bmb Device Id
HVREX_
|
— |
V Ref Sample
HVREX_
|
V |
V Ref Status
HVREX_
|
— |
V Ref Type
HVREX_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a058.