Skip to content

HVREX_a058 — Bmb Vref Bad

Full alert identifier: HVREX_a058_BmbVrefBad

Alert description

Indicates a Battery Monitoring Board (BMB) reference voltage has continuously been out of bounds

Potential impact

Other BMB voltage signals will be substituted given the reference voltage is unreliable

Set condition

Any BMB reference voltage has continuously deviated outside the in-bounds threshold of the nominal voltage

Clear condition

All BMB reference voltages continuously remain within the in-bounds threshold of the nominal voltage

Signals to check

These diagnostic fields are associated with HVREX_a058. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bmb Device Id HVREX_a058_bmbDeviceId —
V Ref Sample HVREX_a058_vRefSample V
V Ref Status HVREX_a058_vRefStatus
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
V Ref Type HVREX_a058_vRefType
0
V5
1
V3
2
REF2
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a058.

Browse all HVREX alert codes