HVBATT_a500 — Hv Mon Bmb Over Voltage

Full alert identifier: HVBATT_a500_HvMonBmbOverVoltage

Alert description

A brick voltage is above the fault voltage limit

Potential impact

The vehicle may not drive or charge.

Set condition

A brick voltage is above the fault voltage limit for X duration (in seconds)

Clear condition

All brick voltages are below fault voltage limit

Signals to check

These diagnostic fields are associated with HVBATT_a500. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Brick Voltage Max HVBATT_a500_brickVoltageMax V
Brick Voltage Max Allowed HVBATT_a500_brickVoltageMaxAllowed V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a500.